Go to Editorial ManagerThis research studied the critical load of composite columns theoretical and numerical by using ANSYS14 package depended on experimental tensile properties of composite specimens. The composite specimens were prepared by hand lay-up technique made from unsaturated polyester reinforced with glass fibers with different fiber volume fraction V f , aspect ratio (L/T), and angle of fibers for coarse and fine woven fibers. The critical load that obtained by using program (ANSYS 14) have also shown a good agreement with results that were obtained theoretically and the maximum difference was (0.7%). The results show that the maximum value of the critical load can be observed at V f =11%, L/T = (3.5) and θ = (0 º /90 º ) for fine woven fibers was (622.115N). Also its found the maximum critical load for coarse woven fibers can be observed at V f %=8%, L/T=(3.5) and θ = (0 º /90 º ) was (486.887N). Also the observed values of tensile properties and predicated values are scattered close to the (45 ˚ ) line.
Solar chimney (SC) together with earth to air heat exchanger (EAHE) is being employed as a low-energy consuming technique to remove undesirable interior heat from a building in the hot seasons. A numerical program "FLUENT 6.3 code" of an earth to air heat exchanger (EAHE) is studied for predicting the outlet air temperature and cooling potential of these devices in Basrah climate. Theoretical analyses have been conducted in order to investigate the ventilation in a solar chimney. The investigation into the viability of Low Energy Earth Pipe Cooling Technology in providing thermal comfort in Basrah. The demand for air-conditioning in buildings in Basrah affects the country escalating energy consumption. Therefore, this investigation was intended to seek for an alternative passive cooling to air-conditioning. The passive technology, where the ground was used as a heat sink to produce cooler air, has not been investigated systematically in hot and humid countries. A sub-soil temperature model adapted for the specific conditions in Basrah is presented and its output compared with CFD modeling. The results have shown that the potential of Earth Pipe is providing lower output temperature of air inlet to the room. We found that the resulting temperature at the buried pipe outlet decreases with increasing pipe length, decreasing pipe diameter, decreasing mass flow rate of flowing air in the pipe and increasing depths up to 4m.
The prediction of the concentration fields of pollutants released to the atmosphere is a key factor in assessing possible environmental damages caused by industrial emissions. To solve the concentration equation for gaseous or particulate effluents it is necessary to know as accurately as possible the velocity field and turbulence intensities at the atmospheric boundary layer in the region of interest. A two dimensional mathematical model based on the equations of fluid mechanics along with a modified non- isotropic k-ε turbulence model are employed to calculate the flow and dispersion at the atmospheric micro scale (distances of the order of kilometers). Results of investigation are obtained by using the finite volume method (FVM) to solve the average Navier Stock equations coupling with turbulent k- ε model. The calculation was carried out for plume flow from the industrial chimney with different plume velocities, wind velocities and heights of stack. The equations of model are solved with SIMPLE schemes. FLUENT program used to show the results of the plume flow at the variable parameters of wind and plume velocities and heights of stack, the code is applied to simulate several cases of flow and dispersion. Comparisons against experimental results show that the non-isotropic turbulence model has better ability to foresee the plume dispersion than the standard k- ε, in which the non-isotropic character of turbulence is relevant. The computational results show that the plume path and concentrations are correctly predicted by the numerical model.
The current approach to cooling water treatment is to use a multi – component inhibitors. Cooling water formulations containing mixtures of inhibitors usually offer better and increased protection to ferrous metals than similar concentrations of either of the individual components. Such mixtures are synergistic in their action .But; the synergistic effects between nitrites, molybdates and inorganic phosphate were not investigated until recently. A weight loss technique was used to investigate such mixture and to optimize the concentrations of the components in the blend.Consequently; an efficient and effective blend was developed as a corrosion inhibitor for carbon steel in aerated Al–Daura refinery re-circulating cooling water in the pH range 6.75 to 7.25. The preferred concentrations of components in the multi- component inhibitor blend (as ppm ) were: (SN + SM): SHMP = 800: 20 with SN: SM weight ratio =3:2.The reduction in corrosion rate was 97.6 % .
In this paper, parallel optical array adder fur large-scale 2D Modified Sign-Digjt (MSD) data array is proposed. and implemented to limit the cany propagation to constant steps. The digit-decomposition-plane (DDP) representation technique is expanded to code the 2D an-ay of the MSD nwnber system. The design is based on the logical fonnul.as which are newly derived according to the fundamental parallel addition algorithm for MSD number system using the . . . . featur~ of the DDP coding technique. The optical im plementations scheme is based on classical optical elementS sucb NJ spatial light modulators, ooam combiner.;, beam splitters, mirrors, light source anays, and light detector arrays. The proposed algorithm and itS optical architecture ~ ve useful intrinsic characteristics such as ultra-high speed, constant processini time, and parallel computation on large-scale data arrays. The simulation results insure lhat the proposed arithmetic unit is worked successfully.