Articles in This Issue
Abstract
There is a vacuum created when water goes past a pipe constriction. Air may be pulled into the main flow by drilling a hole in the pipe near where the vacuum happens. Venturi aerator is an example of the application in action. A vacuum is formed at the suction holes of the Venturi tube when there is a small difference in pressure between the input and output sides. To demonstrate the link between total flow rate and Venturi aerator performance, a Venturi aerator (model 1584) was introduced at a specific point in a Biopipe system. For this purpose, a physical model on a pilot scale was constructed and installed in an existing sewage treatment plant. Dissolved oxygen concentrations were measured at four locations along the Biopipe at different values of wastewater flowrates. The study results showed that raising the total flow rate increased the amount of air injected by the Venturi aerator. When the total flow rate was less than 4 m 3 /hour, the Venturi aerator stops sucking air and produces negative consequences.
Abstract
Chemical additives were used in this research to improve the properties of the road subgrade layer. Cement, lime, and ferric chloride were used. Laboratory tests such as unconfined compressive strength, consistency limits, and wheel truck test were conducted. The results showed that adding these chemicals to the soil increases the ability of the soil to work, its resistance, and its durability. The optimum percentage of chemical additives that is suitable for the addition to the soil of Al-Nasiriya city were 9 %, 10 %, and 2 % corresponding to cement, lime, and ferric chloride, respectively. According to the unconfined compressive strength test and with increase curing period, which gave good results in improving the strength of the soil. As for the consistency limits, all additives reduced the liquid limit and plasticity index and increased the plastic limit, according to the wheel track test, at 10,000 passes the Rutting depth was 32 mm for natural soil, also the depths were (14, 19, and 17 mm) with chemical additives, respectively.
Abstract
The shear panels of plate girder made from corrugated in the web is investigated in this research. A corrugated web beam of plate is attached in the shear zone of the web as part of an experimental and theoretical investigation into plate girders. In experiments, seven plate girder specimens were tested under two points of load. Six of them were made of different shape of corrugated plate in the web, the last specimen was tested without corrugation as a reference specimen called control. In this study investigated the effected of (corrugation plate, thickness of corrugation with number layers of corrugated and the shape of corrugated plate) on (buckling and ultimate loads also on lateral and vertical deflection) and compared with reference specimen, these specimens have the same dimensions, the main variable was the thickness of the corrugated plate in the web (0.5, 1, and 2) mm, the depth was constant (300 mm). According to results of the experiment, the corrugated plates primarily increase the plate girder's stability. A corrugation of plate increases the buckling load and ultimate load significantly through the contribution of the corrugation to delay buckling of the plate girder in the web. In addition, it was found that increasing the plate-girder thickness leads to increased buckling and ultimate loads, because the stiffness will increase and delay the buckling. Also, the trapezoidal corrugation and the diagonal corrugate that placed perpendicular on the tension field action, give higher buckling and ultimate load than control beam. Ansys (version 17.0) computer program was used in this research represent the steel and nonlinear large structural shell was used to represent the corrugated web beam of the plate in the finite element analysis model.
Abstract
This paper investigates the possibility of recycled aggregate use in concrete slabs with hollow cores. The main variables considered in the experimental study for the slabs were the recycled aggregate percentage and the hollow core number. Six slabs with dimensions of (1000 × 500 × 120) mm was fabricated and tested. The results showed that the addition of recycled aggregate in the concrete slabs affected the ultimate strength, ductility, and energy absorption of the concrete members. An increase of the recycled aggregate percentage to 25 % decreased the ultimate strength capacity by 3.54 %, but the increase of recycled aggregate to 50 % led to a decrease in the ultimate strength of about 6.64%. The existence of a hollow core reduced the cracking and ultimate load capacity of the RCA slabs, and this reduction was according to the core number which the fabrication of more cores caused more decrement. The ductility and energy absorption were decreased when the replacement ratio of the recycled aggregate increased. Also, the core number affected the ductility and energy absorption. The energy absorption was the most property affected by the core number increase which caused an average reduction of 71.5 % when the core number increased from two to three hollow cores.
Abstract
This numerical study was conducted to simulate and analyze the pushout test for the new shear connector in a new steel-concrete composite system. In this system, the shear stirrups of the reinforced concrete beam are used as shear connectors when passed through holes drilled in the web of inverted steel T-section. The numerical analysis was performed by creating a three-dimensional finite element model using the finite element program ANSYS 21 student version to simulate the behavior of the new innovative shear connectors. The pushout specimens analyzed in this study have been tested experimentally by the same researchers earlier. A total of fifty-six push-out specimens were modeled and analyzed to investigate the effect of many parameters on the shear strength and slip capacity of the shear connector. The parameters studied in this investigation were the specimen dimensions (length and width), the diameter of stirrups (shear connector), the number of connectors per specimen, concrete strength, size of T-section, and shape of the specimen. The finite element analysis using ANSYS gave a good prediction of the effect of studied parameters on connector strength, the failure modes, the form and intensity of deformations in the model, and the load-slip response. The maximum difference in connector strength which was observed between the numerical and experimental results was 15 %.
Abstract
The trend of using natural fibers in geotechnical engineering has become of great interest to improve weak soils due to some of its advantages such as local availability, environmental friendliness, and lower cost. In this study, a set of unconfined compression strength and direct shear tests were conducted to evaluate the performance of Al-Nasiriya clayey soil reinforced with natural fibers. Three different types of natural fibers were investigated as sustainable ones, including wheat straw fiber and palm frond fiber, as well as imperata cylindrica fiber. The effects of various fiber contents (0.25 %, 0.5 %, 0.75 %, and 1 %) and lengths (20 mm, 30 mm, and 40 mm) were experimentally evaluated. The results indicated that the compressive strength increased significantly with the increase of fiber content and length up to an optimum value and then decreased. The optimum fiber content and length were 0.5 % and 30 mm, respectively. Compared to the unreinforced soil, the compressive strength values at the optimum content and length increased by 102 %, 126 %, and 66 % for samples reinforced with wheat straw, palm fronds, and imperata cylindrica fibers, respectively. The shear properties improved due to soil reinforcement with natural fibers. Compared to the unreinforced soil, the internal friction angle of the samples reinforced with wheat straw, palm fronds, and imperata cylindrica fibers increased by 17.7 %, 42 %, and 9 %, respectively. Forever, the cohesion and shear strength are also improved due to inclusion of natural fibers.
Abstract
Groundwater in arid and semi-arid regions, such as the studied area (Safwan Al-Zubair area, south of Iraq), is of specific meaning as a major source for domestic use and irrigation demand. There is a need to better understand the interactions between groundwater and surface water (Shatt Al-Basrah Canal). These interactions can negatively affect the quality of groundwater in this area, especially that the water of Shatt Al- Basrah Canal contains highly concentrated pollutants. The aim of the study is to investigate the temporal disparity of river-aquifer interactions and count the amount of river interchange among canal and aquifer. In this research, a new concept of paradigm will be advanced utilizing RIVER package of Groundwater River Paradigm (MODFLOW) for the simulation of river-aquifer interaction operations. Six monitoring wells are chosen to evaluate the preliminary and historical groundwater hydraulic heads for six months and then use all collected data in Modflow to execute the simulation of numerical modeling to assessment the interaction between surface water and groundwater. The amount of seepage out from the canal towards the aquifer was (64.99 m 3 /day) in wet season (winter season), as a result of the high levels of the surface water compared to the hydraulic heads of groundwater. The amount of seepage in dry season towards the aquifer is equal to (336.8 m 3 /day).
Abstract
Today, with the continuous increase in the use of computer networks and the rapid evolution of information technologies. The secure transmission of data over the Internet has become an urgent necessity to preserve the privacy of users and protect sensitive information from theft and distortion. images are most of this transferred data, so it was necessary to protect it by encrypting them using algorithms that ensure the protection of information access to the receiver. Color images contain sensitive information and details that must be secured and protected. This paper produces a comprehensive review of image encryption methods and classifies them based on various concepts such as chaotic maps, DNA, etc. with comparisons between existing approaches to accessing different security parameters. Additionally, the types of encryption keys were reviewed along with some common types of attacks and the most important methods for measuring encryption efficiency.
Abstract
Zinc and its alloy coatings are commonly used to provide cathodic protection for weathering steel. However, the steel substrate corrodes faster than the Zinc coating because of the coating's negative corrosion potential. Many studies have examined Zinc and alloy coatings' resistance to corrosion. Hot-dip galvanizing, Electrodeposition, and Zinc-rich coat (ZRC) spray are just some of the methods that can be used to deposit such coatings. Commercially available 99.95 % pure Zinc oxide was used in the electroplating process in this investigation. Steel samples were plated in Zinc sulphate and Zinc oxide solutions and were controlled by different bath parameters such as voltage, current, pH, temperature, and coating time. The addition of hexagonal Boron Nitride (h-BN) nanoparticles has also shown significant improvements in corrosion resistance. However, Zinc-based coating techniques reinforced with h-BN incorporation show the best corrosion current density ( I corr ) of Hot dip 2 % wt. (2.1 µA/cm 2 ), ZRC 2.5 % wt., (4.4 µA/cm 2 ), and electroplating 15.75 g/L (0.081 µA/cm 2 ), which is an order of magnitude lower than coatings without h-BNs. The corrosion rates and current densities of Zn/h-BN coated layers were investigated in a controlled laboratory environment that mimicked natural conditions (Rainwater solution) by extrapolating polarization curves.
Abstract
In this paper friction stir welding process has been studied whereby utilized FEM method (Ansys software ver. 20). The main effective parameter in this process were rotational speed, linear speed, tool shoulder radius, heat transfer coefficient and clamping percentage to study their influence on represent temperature, von misses stress and frictional stress distribution. Because of the difficulty to obtained the number of the simulation cases in order to get the most important results, Taguchi L27 orthogonal array was apply to reduce the total number of the simulation cases. Pure copper (t = 3.18 mm) material type was applied as work plate material. ANOVA statistical tool was utilized to achieved the optimization process after the simulation cases done. Percentage of contribution of each parameter can be obtained by ANOVA table and mean of S/N ratio plot. Validation process was achieved between the Current study and experiment work in the temperature distribution field with percentage of error 2.7 %. From optimization result It is found that the optimum condition in order to obtained good results for temperature was rotational speed of (450 rpm), linear speed (2.75 mm/s), tool shoulder radius (7 mm), heat transfer coefficient (300 w/m 2 K), clamping distance percentage (40 %). And for von misses stress was rotational speed of (550 rpm), linear speed (3 mm/s), tool shoulder radius (7 mm), heat transfer coefficient (300 w/m 2 K), clamping distance percentage (20 %). While for frictional stress was rotational speed of (450 rpm), linear speed (2.5 mm/s), tool shoulder radius (7 mm), heat transfer coefficient (300 w/m 2 K), clamping distance percentage (30 %).
Abstract
This study investigated the performance of symmetric airfoils of type NACA0012 numerically under different operating conditions. It has been assumed that the study involves steady state, non-compressive, and turbulent flows. The operating fluid was air. The effect of Reynolds number and angle of attack on lift and drag coefficients, pressure distribution, and velocity distribution was investigated. ANSYS FLUENT has been used to solve the numerical model by using continuity equations, Navier-Stokes equations, and the appropriate K-ω SST perturbation model. This study shows a clear difference between the pressure coefficient of the lower and upper surfaces of the airfoil at high Reynolds numbers, indicating higher lift at high Reynolds numbers. As the maximum stall angle of the airfoil NACA0012 is 14° after which it decreases significantly, a direct relationship was observed between lift and drag coefficients and angle of attack.
Abstract
Thermal steam power plants represent the most important and dependable type for supplying the base load of electricity around the world. The thermos-economic analysis is an important tool for improving the performance of thermal steam power plants. In the present study, a thermo-economic analysis of a simple steam power plant for different boiler pressure was performed. The analysis comprises the energy, exergy, entropy, economics, and exergy-economic of a simple cycle steam power plant for different boiler pressure. The analysis was performed for a simple steam power plant with the constant output power of 10 MW and the boiler pressure is varied from 10 bar to 100 bar by a step of 10 bar. For each boiler pressure and constant output power, firstly, the fuel mass flow rate, steam flow rate, energy and exergy efficiency, and cost of electricity were calculated. Secondly, entropy generation, exergy destruction, and exergy efficiency for each component were calculated. Finally, exergy destruction economics for each component of the plant was performed. The results reveal that increasing the boiler pressure from (10 to 100 bar) for constant output power reduces the cost of electricity from (0.135 to 0.1025 $/kWh) due to a decrease in the fuel mass flow rate and an improvement in the thermal cycle and exergy efficiency. Also, when the boiler pressure increases, the exergy destruction for the pump increases, the exergy destruction for the boiler decreases, the exergy destruction for the turbine increases, and the exergy destruction for the condenser decrease.
Abstract
The steady-state natural convection from heat sink fin arrays was studied on horizontal, vertical, and inclined heat sinks. Under natural convection, horizontal and vertical heat sinks with parallel fins were tested by considering radiation heat transfer. The experiments were conducted with power inputs ranging from 60 W to 455 W in order to obtain different temperatures. According to the result, when heat input increases, the heat transfer coefficient increases by 38 %, 40.78 % for horizontal and vertical respectively. For horizontal and vertical cases, new correlations have been presented to calculate the Nusselt number influenced by the Rayleigh number. For the incline case, the effect of buoyancy force was studied by changing the inclination angles at 0, 30, 45, and 60 degrees from vertical position. According to comparisons between vertical and incline cases, Nusselt number and heat transfer coefficient were most improved at 30 degrees by 6 %.
Abstract
The purpose of this paper is to determine a stress intensity factor experimental and numerically in the linear region by using a CT specimen of ductile material with a thickness of 15 mm, a width of 30 mm, and pre-crack 1.3 mm this dimension according to ASTM-E399-12 [1], by pulling the specimen in a 600 kN universal testing machine at a very slow speed rate of 0.5 mm/min. The load is applied until the fracture is accrued, the computer-controlled universal testing machine gives the value of the load and the displacement transducer gives a crack mouth opening displacement. The result showed experimental K I is equal to 75.412 MPa √ m, and numerical K I is equal to74.576 MPa √ m, this test showed a very slight decrease in FEA stress intensity factor compared to that in an experimental result which means the stress intensity factor, K I remains very close between experimental and numerical with an error percentage of about (1.12 %). The finite element analysis provides the best approximation to true fracture toughness values, and it can be used to acquire close parameters if experimental testing is not possible.
Abstract
This paper presented experimental and numerical studies to investigate pressure drop in perforation horizontal wellbore with a 90° phasing and 20 spm perforation density. The experimental apparatus has been constructed to calculate the static pressure drop and calculate the exit velocity in the horizontal pipe after mixing the axial flow with the radial flow through the perforations in the wellbore. The specifications of the wellbore used were the inner diameter is 44 mm, length is 2 m, and perforation diameter is 4 mm. For this objective, a simulation model was created in the wellbore using the ANSYS Fluent simulation software by using the standard k-ε model and applied to the (CFD) by changing the axial flow from (40-160) lit/min and constant inflow through perforations from range (0 - 80) lit/min. According to the study's findings, the increase in the radial flow through the perforations increases the total flow rate ratio and the total pressure drop and vice versa. In addition, an increase in the axial flow mixed with radial flow increases the total pressure drop, friction factor, and a decrease in productivity index. Furthermore, the percentage error of the total pressure drop between the numerical and experimental results in test 4 is about 3.83 %. It was found that the numerical and experimental results represented a good agreement about the study of the flow-through perforations at 90° angle in terms of pressure drop and productivity index, etc.