Articles in This Issue
Abstract
Retained Austenite (RA) has great deal with the me- chanical properties of high strength low alloy steel. Therefore, in this paper, Retained Austenite volume fractions have been evaluated in AISI4340 alloy steel using two well-known meth- ods, X-Ray diffraction (XRD) and magnetic measurement methods. The specimens were heat treated using different heat- ing temperature and different cooling rate (different quenching media). A comparison between the results of two methods proved that there results were approximately Identical .The results show that Retained Austenite formation increase as heating (Austenizing ) temperature increase for the same quenching media ,as well as ,it increases by increasing cooling rate . The maximum amount of Retained Austenite found as (27.2 Wt %) which recognized when the specimens heated up to 1000˚C then quenched in Water while the minimum amount of Retained Austenite found as ( 7.06 wt%) when the specimens heated up to ( 800 ˚C) then quenched in Sand. Hardness tests using Vickers and Rockwell methods were used and the results show that hardness values decreased with increasing heating temperatures and the maximum Vickers micro-hardness and Rockwell hardness numbers were equal to (121.8HRB) and ( 516.35 HV) which were detected when heating up of the speci- mens were up to 800 ˚C then quenched in water. Tensile tests show that increasing cooling rate lead to increasing in Strength due to increasing of hardness which in turn, leads to increase in yielding points and ultimate strengths. Retained austenite effects on microstructure were investigated using scanning electron microscopy (SEM) and optical microscopy and the results show that at low cooling rate the microstructure consist of bainite and/or martensite phase with small amount of re- tained austenite, while, increasing heating temperature and cooling rate results in microstructure consist of martensite and retained austenite phases.
Abstract
The present study aims to investigate the influence of heat treatment and surface finish on the behavior of crevice corrosion resistance of AISI 410 and 416 martensitic stainless steels thus, to quantify the conditions at which crevice corrosion minimize as possible. The experimental work carried out during this study involves material selection, chemical composition tests, specimens preparation before heat treatments, austenitizing at temperature range (925-1010˚C) and for holding time periods of (30, 45 and 90 min), air and oil quenching followed by tempering at heating range of (205- 605 ̊C) and for 45 min, micro hardness tests, specimens grinding, surface roughness measurements, crevice corrosion tests, crevice evaluation and microstructure tests. Theoretically, empirical equations for crevice maximum depth under the effect of surface roughness and hardness for both AISI 410 and 416 steels were determined. While for microstructure analysis, carbides average area was determined by using the ImageJ analysis program and a mathematical model was also predicted. Results showed that, as hardness and surface roughness increase crevice corrosion resistance decreases. Therefore, material treated by annealing can minimize crevice corrosion rates more than that treated with hardening.
Abstract
This paper introduces a radial distribution feeder protection scheme based on certain features extraction from current signals measurement at the substation. The features are captured using the discrete wavelet transform (DWT). Two digital signals processing methods are used to introduce those features to the 1) fault detection 2) identification and 3) localization schemes; the first one is the energy method and the second one is the root mean square method. For the purpose of fault type identification, two systems are tested and compared, a Fuzzy Inference System (FIS) and Artificial Neural Network (ANN). Fault location scheme is then built based on ANNs. An effort is made to reduce the computational burden and the speed of detection provided by the fault detection and identification schemes. Since the short circuit faults are the most likely types of faults that can occur in power systems, the ten types of these faults taking into account different fault resistances are simulated in MATLAB environment and the protection scheme is built based on the idea of over current. The power quality disturbances such as switching transient events on the feeder is also taken into account in order to build a reliable and secure protection scheme.
Abstract
This paper presents design and modeling of a compact reconfigurable quarter wavelength slot antenna compatible with the portable devices of the 5GHz wireless local area network (WLAN) applications. The concept of the transverse resonant method which is used for the transmission lines is utilized for modeling the proposed slot antenna. A PIN diode is used to switch the antenna operating band from the lower unlicensed indoor 5GHz WLAN band (5-5.3) GHz to the upper one (5.7-5.9) GHz and vice versa. Another PIN diode is attached to the feed line to provide suitable matching stub length for each operation mode. Furthermore, the shape of the radiating slot of the proposed antenna is modified to provide an omnidirectional radiation pattern in the H-plane suitable for the portable gadgets of the WLAN system. The measurements are in well agreement with the simulated results, and they verify the precision of the suggested model and the enhanced matching characteristics for the two operation modes of the proposed antenna.
Abstract
The surge tank is one of important control devices in reducing water Hummer effect on distributed network piping system and hydropower stations. An experimental study was conducted into a simple surge tank of 0.044 m in a diameter with upstream constant head reservoir of a height, 0.881 m and a water transporting pipe of a size 0.0202 m. Results indicate that rapid closure of a downstream valve causes under-damped stable oscillation in a surge tank. Experimental response agreed well with theoretical results when friction factor is considered to be variable, but with 85 % increases in settle time and more oscillations when constant friction factor is recognized at initial value before valve closure. Doubling surge tank area does not improve the dynamics properties; otherwise, Thoma area must be avoided for small sizes. Comsol multiphysics software 3.5 is used to deal with the dynamics of the surge tank numerically.
Abstract
This paper is concerned with the design of a new controller for active suspension system. The model is considered as a quarter-car. The presented controller depends on the fuzzy technique and NARMA-L2 linearization algorithm. The compensation system that added by the fuzzy rules improves the performance of the controller, while the neural network produces the required control signal. The new controller can achieve an improvement of the ride comfort with a reasonable value of power consumption. The mathematical analysis of the mechanical power used by the model is focused on the average and the RMS of the power supplied to the system, regardless of the frequency content of the vibration signal. The simulation results which are verified by a practical examples of road profiles, demonstrate the efficacy of the proposed controller.