×
The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerThe objective of the present paper is to evaluate the effects of the soil-structure interaction on the seismic evaluation in the building when a framed building is supported on raft foundation. Also the foundation-soil interaction effect has been considered by replacing it with equivalent springs. Nonlinear static pushover analyses of eight-storey reinforced concrete hospital building located at Delhi-India has been performed using the Capacity Spectrum Method of ATC-40. The deformations define the state of damage in the structure through three limit states of the NEHRP Guidelines and the FEMA-356 have been used to evaluate the performance level of the building for drift, the plastic hinge stage of the crack and shear under the condition of the fixed base and the effect of the soil-structure interaction. The performance of the building and individual components has been estimated for Design Basis Earthquake and Maximum Considered Earthquake. The weight of the slab was distributed as triangular and trapezoidal loads to the surrounding beams as per IS 456:2000. The weight of the brick masonry was distributed uniformly on the beams. The results show that the soil structure interaction has marked effect on the roof displacement, storey drift, design base shear, effective damping and crack pattern for beams and columns while there is a minor effect on the torsional behavior of the building. The building is more critical in the performance level when considering the soil flexibility.
Fracture mechanics approach is important for all mechanical and civil projects that might involve cracks in metallic materials the purpose of this paper is to determine a crack tip opening displacement fracture toughness experimentally, also study the effect of thickness on CTOD fracture toughness of low carbon steel and study the effect of Wire Electrical Discharge Machine (WEDM) to have a pre-crack, instead of fatigue pre-crack by using a CT specimen of low carbon steel with a thickness of (8,10, and15 mm), a width of 30mm, crack length of 15mm, and pre-crack of 1.3mm for all samples, this dimension according to ASTM-E399-13, by pulling the specimen in a 100 KN universal testing machine at a slow speed rate of 0.5 mm/min, the load applied on the specimen is generally a tension load. The crack tip plastically deforms until a critical point P C at this moment a crack is initiated. The computer-controlled universal testing machine gives the value of the load and the displacement transducer gives a crack mouth opening displacement. Critical crack tip opening displacement CTOD is found with the plastic hinge model (PHM) method. The result showed the stress intensity factor K I increases with increased loading in the elastic region and t he thickness effect refers to the effect of the plastic zone at the crack tip on the stress intensity factor, In a thin specimen, a plastic zone is large at the fracture tip leads to a high-stress intensity factor at the fracture tip but in the thick specimen, on the other hand, has a small a plastic zone and a low-stress intensity factor around the crack tip. The fracture toughness is found to increase with an increase in the thickness of specimens.