Cover
Vol. 15 No. 1 (2015)

Published: June 30, 2015

Pages: 75-85

Original Article

Effect of Soil –Structure Interaction on Seismic Evaluation of Existing Building Frames Resting on Raft Foundation

Abstract

The objective of the present paper is to evaluate the effects of the soil-structure interaction on the seismic evaluation in the building when a framed building is supported on raft foundation. Also the foundation-soil interaction effect has been considered by replacing it with equivalent springs. Nonlinear static pushover analyses of eight-storey reinforced concrete hospital building located at Delhi-India has been performed using the Capacity Spectrum Method of ATC-40. The deformations define the state of damage in the structure through three limit states of the NEHRP Guidelines and the FEMA-356 have been used to evaluate the performance level of the building for drift, the plastic hinge stage of the crack and shear under the condition of the fixed base and the effect of the soil-structure interaction. The performance of the building and individual components has been estimated for Design Basis Earthquake and Maximum Considered Earthquake. The weight of the slab was distributed as triangular and trapezoidal loads to the surrounding beams as per IS 456:2000. The weight of the brick masonry was distributed uniformly on the beams. The results show that the soil structure interaction has marked effect on the roof displacement, storey drift, design base shear, effective damping and crack pattern for beams and columns while there is a minor effect on the torsional behavior of the building. The building is more critical in the performance level when considering the soil flexibility.

References

  1. Applied Technology Council, 1996, "Seismic Evaluation and Retrofit of Concrete Buildings", Report No. SSC 96-01: ATC-40, Vol.1, Redwood City, California, 14- 7 p.
  2. ETABS plus Version 9.7.1, "Extended 3-D Analysis of Building Systems", Computer and Structures, Inc., Berkeley, CA, USA.
  3. Federal Emergency Management Agency, 2000, "Prestandard and Commentary for the Seismic Rehabilitation of Buildings", FEMA-356, Washington, D.C, 11-44 p.
  4. Federal Emergency Management Agency, 1997, "NEHRP Guidelines for the Seismic Rehabilitation of Buildings", FEMA-273, Washington, D.C, 11-31 p.
  5. Jarallah, H.K., Singh,Y. and Paul,D. K., (2006), "Nonlinear Static (Pushover) Analysis of GTB Hospital (Ward Block)", Technical Report No. EQ: 2006-10, Department of Earthquake Engineering, Indian Institute of Technology Roorkee, India, 69 p.
  6. Choudhary, K.U., 2003, "Study Of Soil-Structure Interaction in 2D/3D Building Frames", M.Tech. Thesis, Department of Civil Engineering, Indian Institute of Technology Roorkee, India, 71 p.
  7. Pais, A. and Kausel, E., 1988, "Approximate Formulas for Dynamic Stiffnesses of Rigid Foundations", Soil Dynamics and Earthquake Engineering, Vol.7, No.4, pp. 213-227.
  8. Hemsley, J.A., 2000, "Design Application of Raft Foundation", Published by Thomas Telford Ltd. London, 626 p.
  9. ACI committee 318, 2008," Building Code Requirements for Structural Concrete (ACI 318M-08) and Commentary", American Concrete Institute, Michigan, 473 p.
  10. Indian Standard Criteria for Earthquake Resistant Design of Structures, IS 1893: (Part 1) 2002, Part 1 General Provisions and Buildings (Fifth Revision), Bureau of Indian Standards, New Delhi, India, 39 p.
  11. Indian Standard Code of Practice for Plain and Reinforced Concrete (Fourth Revision), IS 456: 2000, Bureau of Indian Standards, New Delhi, India, 100 p.