The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerIn this study, a numerical investigation has been carried out for single phase flow behavior for thirty six internally finned tubes to demonstrate the effect of axial pitch to fin height ratio (p/e) for 0.8≤p/e≤6.345, helix angle of internal fins (β) for 30°≤β≤70°, apex angle of internal fins (α) for 0°≤α≤53.13°, internal fin height (e) for 0.6mm≤e≤1.0mm, internal tube diameter (di) with 14 mm and Reynolds number (Re) of single phase flow for 10000≤Re≤50000 on enhancement of forced convection heat transfer and reduction of friction factor by using ANSYS CFX program. It solves the three-dimensional Navier-Stokes equations for steady state turbulent with SST model and enhance wall treatment. The numerical analysis provided at fully developed velocity and temperature. Numerical results showed that the smallest axial pitch to fin height ratio (p/e) =0.8 and with apex angle α=10 degree provided enhancement of heat transfer of 2.8 to 3.55 times higher than of smooth tube. Finally, present numerical results are seen to be in good agreement with literature experimental correlations.
In this study, a numerical investigation has been carried out for single phase flow behavior for thirty six internally finned tubes to demonstrate the effect of axial pitch to fin height ratio (p/e) for 0.8≤p/e≤6.345, helix angle of internal fins (β) for 30°≤β≤70°, apex angle of internal fins (α) for 0°≤α≤53.13°, internal fin height (e) for 0.6mm≤e≤1.0mm, internal tube diameter (di) with 14 mm and Reynolds number (Re) of single phase flow for 10000≤Re≤50000 on enhancement of forced convection heat transfer and reduction of friction factor by using ANSYS CFX program. It solves the three- dimensional Navier-Stokes equations for steady state turbulent with SST model and enhance wall treatment. The numerical analysis provided at fully developed velocity and temperature. Numerical results showed that the smallest axial pitch to fin height ratio (p/e) =0.8 and with apex angle α=10 degree provided enhancement of heat transfer of 2.8 to 3.55 times higher than of smooth tube. Finally, present numerical results are seen to be in good agreement with literature experimental correlations.
The effect of different dosages of the high range water reducing admixture–additive- (HRWRA), the commercially polymeric material (Plastocrete-N), on the corrosion resistance of embedded steel in concrete exposed to chloride solution in the absence and presence of sulfate ions was studied. In the present study, four levels of polymeric material (Plastocrete-N) (0.125%, 0.250%, 0.375%, and 0.500% by weight of cement) were used to prepare HRWRA treated concrete. The concrete specimens exposed to chloride and chloride–sulfate solutions at concentrations of (3.5% NaCl and 5% Na2SO4), at ambient temperature. The electrochemical behavior of steel in both reference and HRWRA concretes was studied under the effect of corrosive environments using corrosion measurement systems such as: a) half – cell potentials measurement system and b) accelerated corrosion test system. The results showed that a longer time of corrosion initiation (180 day) observed with 0.500% HRWRA containing concrete compared to other different HRWRA percentage including the reference concrete. It was concluded that the use of 0.500% HRWRA provided superior protection to steel reinforcement in concrete that subjected to corrosive environments. Furthermore, the steel with 0.500% HRWRA was subjected to corrosion test by mass loss, it is evident that a reduction in mass loss by about 90.2% and 85.2% in both solutions, respectively.
In this study, a numerical investigation has been carried out for single phase flow behavior for thirty six internally finned tubes to demonstrate the effect of axial pitch to fin height ratio (p/e) for 0.8≤p/e≤6.345, helix angle of internal fins (β) for 30°≤β≤70°, apex angle of internal fins (α) for 0°≤α≤53.13°, internal fin height (e) for 0.6mm≤e≤1.0mm, internal tube diameter (di) with 14 mm and Reynolds number (Re) of single phase flow for 10000≤Re≤50000 on enhancement of forced convection heat transfer and reduction of friction factor by using ANSYS CFX program. It solves the three- dimensional Navier-Stokes equations for steady state turbulent with SST model and enhance wall treatment. The numerical analysis provided at fully developed velocity and temperature. Numerical results showed that the smallest axial pitch to fin height ratio (p/e) =0.8 and with apex angle α=10 degree provided enhancement of heat transfer of 2.8 to 3.55 times higher than of smooth tube. Finally, present numerical results are seen to be in good agreement with literature experimental correlations.