Go to Editorial ManagerIn the present research, a Matlab program with a graphical user interface (GUI) has been established for studying the performance of a solar tower power plant (STPP). The program gives the ability for predicting the performance of STPP for different tower dimensions, ambient operating conditions and locations. The program is based on the solution of a mathematical model derived from the heat and mass balance for the tower components. The GUI program inputs are; tower dimensions, solar radiation, ambient temperature, pressure, wind velocity, turbine efficiency, emissivity and absorptivity for collector and ground and thermal conductivity and thickness for ground. However, the GUI program outputs are; temperature and pressure differences across the collector and tower, velocity in the tower, density of air in collector outlet, mass flowrate of air, efficiency for collector and tower, the overall efficiency and output power of STPP. The effect of the geometrical dimensions of STPP and some climatic variables on the plant performance was also studied. The results show that the output power increases with increasing the collector diameter, chimney diameter and solar radiation by an increasing of 0.282 kW/m, 0.204 kW/m and 0.046 kW/(W/m2) respectively.
The heat lost from gas turbine power plants with exhaust gases represents the most important source for lowering its thermal efficiency. Also, the gas turbine thermal efficiency affected significantly with the ambient surrounding temperature. Al-Najybia gas-turbine power plant in Basrah, Iraq is choosing as a case study. The power plant consists of four units with a capacity of 125 MW for each unit. In the present study, all the calculations are performed for one unit only. Firstly the thermal impact is studied in terms of energy analysis for Al-Najybia gas turbine power plant (GTPP) for different ambient temperature for twelve months. Also, the economic loss a companied the heat lost with exhaust gases for different ambient temperature are estimated. Secondly, the thermo-economic improvement from coupling the GTPP with a heat recovery system is studied. For gas-steam combined cycle, the performance and economic analysis are performed. The results show that, the output power and thermal efficiency are decreased by 0.97 MW and 0.0726% respectively for each unit temperature rise of the ambient temperature. For the combined gas-steam power plant the percentage increasing of the thermal efficiency is approximately 46.4%. The results indicate the combined cycle power plant (CCPP) is very important to increase electrical capacity. From the economic analysis, the economic gain due to using HRB is 75757 $ per month.
Solar energy is the most suitable among all renewable energy options for competing with fossil fuels in desalination due to its ability to utilize both heat and power for the process. In this study, the Parabolic Trough Solar Collector (PTSC) for powering a Single Stage Flash (SSF) desalination unit was proposed for Basrah city climate, Iraq. The desalination system comprises two directly coupled sub-systems: the PTSC and the SSF desalination unit. The preheated feed brine water coming from condenser was used as a Heat Transfer Fluid (HTF) for PTSC, which gets heated to a desired temperature referred to as the Top Brine Temperature (TBT). The numerical simulations were performed via EBSILON professional 16.02 (2022) software. The effects of TBT, mass flowrate of feed brine water to get the desired TBT, solar collector area, and vacuum pressure inside flash chamber on the performance of the desalination system was studied. A major finding of the current study can be summarized as follows: The collector efficiency is enhanced eventually as TBT increases. The maximum values of distillate water in June are around 5.5, 4.56, 3.69, 2.75 and 1.85 kg/h for 12.408, 10.434, 8.3472, 6.26, and 4.1736 m² collector area respectively, when TBT 107 °C and vacuum pressure 40 kPa. For 1.598 m² collector area, the total distillate in the 1st of June amounted to 7.9 kg, with an average production rate of around 0.7 kg/h. The solar SSF system's productivity per solar collector unit area at 20 kPa, 15 kPa, and 10 kPa vacuum pressures was 4.7 kg/day/m², 5.3 kg/day/m², and 6.25 kg/day/m², respectively. The average Performance Ratio (PR) values are determined to be 0.694, 0.577, and 0.491 for 10 kPa, 15 kPa, and 20 kPa, respectively. These results are very acceptable when compared with an existing literature.
A household refrigerator represents an essential device for all houses nowadays. The electric energy consumed by the refrigerator and the fluctuation of the temperature inside the fresh food cabin is the main two problems affecting its performance. Incorporating phase change material (PCM) inside the refrigerator is one of the solutions for the previous mentioned problems. In the present study, a water PCM is added to the cabinet of 220-litters double door refrigerator. The PCM (0.5 ml of water) is added at three different locations, touch the front of the evaporator part inside the cabin, touch the rear of the evaporator part in the cabin, and far away from the evaporator part inside the cabin. The location of the PCM determines how much energy is released and stored from the evaporator. The use of phase change material (PCM) touch to the evaporator increases the rate of heat transfer due to the conduction method being used throughout the whole heat transfer process from the evaporator to the phase change material (PCM), which raises the refrigeration system's COP (coefficient of performance). The experimental test period is 24 hours for each day. Firstly, the refrigerator is tested without using PCM, and the power consumption, the temperatures at different points for the refrigerator, suction pressure, discharge pressure, the ambient temperature, and the time on period and time off period of the compressor are measured. Secondly, for same testing period all previous parameters are measured with using PCM at different locations inside the refrigerator. The results show that, adding the PCM (water) behind the evaporator led to increase the COP by 21.97%, increase the compressor off time by 73 minutes, reduction in power consumption of 14.4%, decrease of exergy losses of the system by 8% and temperature fluctuation reduced inside the fresh food cabin, that enhance the quality of stored food. Adding the PCM front the evaporator improve the previous parameters but less than that of the first case. The third location, adding the PCM far away from the evaporator has no improvement on the refrigerator's performance.
The steady-state natural convection from heat sink fin arrays was studied on horizontal, vertical, and inclined heat sinks. Under natural convection, horizontal and vertical heat sinks with parallel fins were tested by considering radiation heat transfer. The experiments were conducted with power inputs ranging from 60 W to 455 W in order to obtain different temperatures. According to the result, when heat input increases, the heat transfer coefficient increases by 38 %, 40.78 % for horizontal and vertical respectively. For horizontal and vertical cases, new correlations have been presented to calculate the Nusselt number influenced by the Rayleigh number. For the incline case, the effect of buoyancy force was studied by changing the inclination angles at 0, 30, 45, and 60 degrees from vertical position. According to comparisons between vertical and incline cases, Nusselt number and heat transfer coefficient were most improved at 30 degrees by 6 %.