Basrah Journal for Engineering Sciences
Login
Basrah Journal for Engineering Sciences
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Announcements
    • Contact

Search Results for up-in-and-up-out-ventilation

Article
Indoor Air Quality in a Cardiac Care Unit (CCU) under Different Ventilations

Abdulhadi M. Salman, Ali A. Monem, Emad A. Khazal

Pages: 1-7

PDF Full Text
Abstract

A proper ventilation offered warranty for a perfect indoor environment. Indoor air environment includes indoor thermal environment and indoor air quality (IAQ). In this paper a numerical investigation of the indoor environment in different ventilations was accomplished. The Cardiac Care Unit (CCU) in Al-Rifai hospital in Thi-Qar governorate was chosen to be investigated, and its thermal achievement and indoor air quality in the hot summer weather were simulated. For the numerical study, the fluent technique used to set up the physical and numerical model of CCU. An attention has been paid carefully to considerate the distributions of the temperature and the velocity fields, followed by an argument of two different ventilation patterns; up-in and up-out ventilation (UV) and displacement ventilation (DV). After making the comparison, it was noticed that the displacement ventilation (DV) is clearly super than that of the up-in and up-out ventilation (UV) due to improvement in the indoor air quality.

Article
Hourly Cooling Load Assessment Utilizing Three Different Methods for a Full Day

Feras Mutar Khalaf, Hussein S. Sultan, Ahmed Kadhim Alshara

Pages: 24-31

PDF Full Text
Abstract

Human beings are facing an unprecedented rise in temperature rates not recorded for years. HVAC (heating, ventilation, and air conditioning) systems have been created and enhanced to solve this issue. Cooling load must be estimated with accepted methodologies before designing an efficient and effective air conditioning system. Companies, researchers, institutions, and others advise and develop many cooling load calculation methods. Each one of these methods has its advantages and disadvantages and may give a slightly different result for the same case. For each building, whether it was residential or commercial buildings, gyms, or shopping malls, before making the decision on (HVAC) systems to be used, both heating and cooling loads should be obtained as correctly as possible to minimize expenses as possible. Since the HVAC system consumes the most energy in an air-conditioned building, an accurate method of cooling load estimation is necessary. Consequently, an energy-efficient air conditioning system reduces greenhouse gas emissions into the atmosphere while also saving money on electricity. Two cases have been compared and studied, one in Dubai UAE, and the other in Baghdad Iraq. Three different methods, HAP, hand calculation method (CLTD/SCL/CLF), and MS-EXCEL E20 form sheet were used to compare the accuracy of the results for cooling load. Results of E20 and HAP are very close to each other with high accuracy for peak load, the big difference can be found between the CLTD method and the other two methods. The value of the maximum difference percentage was found between CLTD and E20 equals 3.28% and 7.96%, on the other hand, the lowest difference was equals to 0.3% and 1.51% between HAP and E20 results for Baghdad and Dubai respectively. Traditional and local materials came from local factories, used in buildings played a big effect on the results, which may not match those materials stated in the ASHRAE or CARRIER tables, which need to be considered in the results and calculation procedure. However, all methods have a percentage of difference but all results are within the accepted range and are applicable for practical cases. Of course, this percentage is minimal with some methods and maximum with others.

Article
Modelling and Solution of Trapezoidal Variable Orifice Flow Meter: 3D Fluid - Structure Interaction

Rana K. Shamkhi, Mohammad Ghalambaz, Muneer A. Ismael

Pages: 1-10

PDF Full Text
Abstract

Gas flow measurements are pivotal in several medical applications. For instance, mechanical ventilators and respiratory monitoring applications need flowmeters with strict requirements. This study is concerned with a three-dimensional computational fluid dynamics (CFD) analysis. The CFD methodology was confirmed by analyzing the flow characteristics of flexible membrane with trapezoidal orifice plates. Variable area orifice meters (VAOMs) are increasingly being embraced in respiratory monitoring applications, employed in the context of mechanical ventilation within medical settings. Each system integrates a flexible orifice plate within the conduit. The simulations are conducted considering realistic deformations in structure through two-way fluid-structure interactions (FSI) using the Arbitrary-Lagrangian-Eulerian (ALE) approach. This research paper analyzes using the finite volume method (FVM). A thorough numerical simulation was performed for the turbulence models. The orifice's thickness and shape significantly influence pressure drop and deflection.

Article
Application of Earth Tube Heat Exchanger and Solar Chimney for Natural Cooling System in Basrah City

Salman H. Hammadi, Alaa Hlaichi Mohammed

Pages: 23-32

PDF Full Text
Abstract

Solar chimney (SC) together with earth to air heat exchanger (EAHE) is being employed as a low-energy consuming technique to remove undesirable interior heat from a building in the hot seasons. A numerical program "FLUENT 6.3 code" of an earth to air heat exchanger (EAHE) is studied for predicting the outlet air temperature and cooling potential of these devices in Basrah climate. Theoretical analyses have been conducted in order to investigate the ventilation in a solar chimney. The investigation into the viability of Low Energy Earth Pipe Cooling Technology in providing thermal comfort in Basrah. The demand for air-conditioning in buildings in Basrah affects the country escalating energy consumption. Therefore, this investigation was intended to seek for an alternative passive cooling to air-conditioning. The passive technology, where the ground was used as a heat sink to produce cooler air, has not been investigated systematically in hot and humid countries. A sub-soil temperature model adapted for the specific conditions in Basrah is presented and its output compared with CFD modeling. The results have shown that the potential of Earth Pipe is providing lower output temperature of air inlet to the room. We found that the resulting temperature at the buried pipe outlet decreases with increasing pipe length, decreasing pipe diameter, decreasing mass flow rate of flowing air in the pipe and increasing depths up to 4m.

1 - 4 of 4 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Basrah Journal for Engineering Sciences

College of Engineering, University of Basrah

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, University of Basrah, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.