The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerThe study aimed to investigate the structural behavior of indirectly loaded flanged deep reinforced concrete beams. Twenty-one flanged deep beams were tested. The behavior of beams under loading was observed. Cracking and ultimate loads were recorded.
This study investigates the effect of the shear span-to-effective depth ratio (a/d) on the behavior of high-strength steel fiber–reinforced concrete deep beams without stirrups containing circular web openings. A circular opening of 12.6 cm diameter was positioned at the center of the shear span, and beam performance was evaluated in terms of crack patterns, load–deflection response, and stress–strain behavior. Four specimens were tested experimentally. The control specimen consisted of a solid deep beam without openings and without steel fibers, while the remaining three specimens were reinforced with 1% steel fibers and included circular openings. All specimens were reinforced with 2Ø12 mm top bars, 3Ø16 mm bottom bars, and two stirrups at the supports to prevent local failure. The beams had different shear span ratios (a/d = 0.75, 1.0, and 1.5) and corresponding total lengths of 1025 mm, 1200 mm, and 1550 mm, respectively. All specimens were simply supported and subjected to two-point loading. The experimental results revealed that the optimal shear span ratio for maximum performance was a/d = 0.75 when combined with 1% steel fiber reinforcement. In addition, the ultimate strength of beams with circular openings decreased as a/d increased, with a strength increase of approximately 5.48% at a/d = 0.75 compared with a/d = 1.0.
This research is devoted to investigate the effect of Carbon Fibre Reinforced Polymer (CFRP) strips on the behaviour and load carrying capacity of strengthened and repaired reinforced concrete corbels. Experimental investigation were carried. The experimental program variables include location, direction, amount of CFRP strips and effect of shear span to effective depth (a/d) ratio on the behaviour of strengthened corbels. All corbels had the same dimensions and flexural reinforcement and they were without horizontal shear steel reinforcement. The experimental results obtained from the adopted strengthening and repairing CFRP techniques showed a significant improvement in the behaviour and carrying capacity of the tested corbels. An increase of about (44.5 - 60) % in the ultimate load has been obtained for specimens strengthening by inclined technique compared to the ultimate load of control corbel and (14.7 - 31.2)% for specimens strengthening horizontal technique. For corbels repaired with CFRP strips, an increase of (56%) with respect to the ultimate load of control corbel is achieved. Also the strengthened corbels show stiffer load deflection response than corresponding control corbels (unstrengthened corbels).