The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerMathematical programming techniques have been used to minimize the cost of reinforced concrete T-beam floor. The floor system consists of one way continuous slab and simply supported T-beams. The study presents a formulation based on elastic analysis followed by the ultimate strength method of design with the consideration of serviceability constraints as per ACI Code. The formulation of optimization problem has been made by utilizing the interior penalty function method as an optimization method with the purpose of minimizing the objective function representing the cost of one-meter length of the floor system. The cost includes cost of concrete, reinforcement, and formwork. The design variables considered in this study are the dimensions and the amounts of reinforcement for the slab and beams, in addition to the spacing of the beams. Many examples are solved to show the effect of these design variables on the optimum solution of the floor system. The effect on the optimum design of the compressive strength of concrete, yield strength of steel, concrete cost ratios, and formwork cost ratios has also been studied.
New composite reinforced concrete beams, in which reinforced concrete component is connected to steel T-section, are proposed. The stirrups of the beam were utilized as shear connectors by passing them through drilled holes in the web of the steel T-section. Experimental test and numerical analysis were conducted to determine the behaviour of such beams when subjected to combined shear, torsion, and bending stresses. Full scale one conventional reinforced concrete curved in plan beam C1, and four composite reinforced concrete ones, C2 to C5, were tested. The degree of shear connection between the two components of beams C2 to C5 was changed by varying the number of stirrups which are used as shear connectors. The increase in load carrying capacity of the composite reinforced concrete beams reached 55 % for beam C4 as compared to that of ordinary reinforced concrete beam. The experimental results demonstrated that the stirrups are very effective in providing the interaction between the two components of the beams. The degree of shear connection emerged not to have effect on the behaviour of tested beams. Three-dimensional finite element analysis was conducted using commercial software ABAQUS. To model the shear connection in composite reinforced concrete beam, the stirrups were connected to the web of the steel T-section by springs at the location of the stirrups. Good agreement is obtained between the results of the experimental tests and the finite element analysis.
A composite beam is an accumulation of different materials so as to form a single unit to exploit the prominent quality of these materials according to their position within the cross-section of the composite beam. The present study investigates the structural behavior of six simply supported composite beams, in which a reinforced concrete T-beam is connected together with a steel channel located at the bottom of a T-beam by means of headed stud shear connectors. The used degrees of shear connection are (100%, 75%, 50%, and 38%). Three dimensional nonlinear finite element analysis has been used to conduct the numerical investigation for the general behavior of beams which are subjected to central point load. ANSYS 12.1 program code was used to estimate the ultimate loads, deflections, stresses, strains, end slip. Concrete was modeled by brick element (SOLID65), while the steel channel was modeled as brick element (SOLID45). Two-node discrete elements (LINK8) are used to represent the steel reinforcement and shear connectors. Perfect bond between the reinforcing rebars and the concrete was assumed. The load on beams was applied monotonically in increments up to failure. The reduction of the degree of shear connection from 100% to 38% causes increasing of strain, mid span deflection and end slip with an average of 3.95%, 13%, and 111% respectively, while the ultimate load decreases with an average of 7.3%. In order to observe the efficiency of the 3-D model, a comparison was made with available experimental work. Good agreement was obtained throughout this work between the finite element and available test results.
In this investigation, the bond stresses between the reinforcement and concrete was studied by using non-material interface elements that are able to produce the bond stresses for the reinforced concrete beam gradually loaded from zero to failure. Depending on (Jawad) program, which is a non-linear analysis program of plain and reinforced concrete beams through a discrete-crack approach by using the finite element method. The stiffness matrix derivation of the interface element and the way of non-linear treatment were explained. The distribution of bond stress drawings along the steel reinforcement for different values of loading was achieved before and after cracking.
This numerical study was conducted to simulate and analyze the pushout test for the new shear connector in a new steel-concrete composite system. In this system, the shear stirrups of the reinforced concrete beam are used as shear connectors when passed through holes drilled in the web of inverted steel T-section. The numerical analysis was performed by creating a three-dimensional finite element model using the finite element program ANSYS 21 student version to simulate the behavior of the new innovative shear connectors. The pushout specimens analyzed in this study have been tested experimentally by the same researchers earlier. A total of fifty-six push-out specimens were modeled and analyzed to investigate the effect of many parameters on the shear strength and slip capacity of the shear connector. The parameters studied in this investigation were the specimen dimensions (length and width), the diameter of stirrups (shear connector), the number of connectors per specimen, concrete strength, size of T-section, and shape of the specimen. The finite element analysis using ANSYS gave a good prediction of the effect of studied parameters on connector strength, the failure modes, the form and intensity of deformations in the model, and the load-slip response. The maximum difference in connector strength which was observed between the numerical and experimental results was 15 %.
This research concerns with the fracture behavior of reinforced concrete beams without shear reinforcement numerically. The software ABAQUS is adapted to simulate the crack propagation using the eXtended Finite Element Method (XFEM), taking into account materials nonlinearities using concrete damage plasticity CDP criteria. XFEM is used to solve the discontinuity problems in the simulation. The maximum principal stress failure criterion is selected for damage initiation, and an energy-based damage evolution law based on a model- independent fracture criterion is selected for damage propagation. The traditional nonlinear finite element analysis is used to specify the crack initiation position, which is required to specify the crack location in the analysis of beams using XFEM. Three-dimensional reinforced concrete beam models are investigated subjected to three and four-point loading tests. Simply supported beams under the effect of applied static load are investigated. An elastic perfectly plastic model is used for modeling the longitudinal steel bars. The main variables considered in the study are beam depth and the shear span with beam length. The numerical results are compared with the available experimental results to demonstrate the applicability of the model. The XFEM provides the capability to predict the concrete member fracture behavior.
A large number of RC structures or at least some of their members need strengthening or rehabilitation. Among the typical failure modes, the shear failure is more dangerous and less predictable, because of usually brittle behavior and sudden collapse. Therefore, there are necessities for upgrading the shear capacity and the local ductility of reinforced concrete beams. In this study, four different techniques of concrete jacketing were used to improve the behaviors of the shear deficiencies beams. The four techniques used in this study to enhance the behavior of the beams were by using a Self-Compacted Fiber Reinforced Concrete jacket without stirrups (S.-J. + Steel Fiber), a concrete jacket of Self Compacted Concrete with stirrups (S.-J. + Stirrups), a concrete jacket of ferrocement jacket (S.-J. + Ferrocement), and a concrete jacket of ferrocement jacket with external steel reinforcing bars (S.-J. + Ferrocement + R). These techniques contributed to enhancing the load-carrying capacity and delaying the appearance of the first crack in tested beams compared with the control beam by a percentage of (35, 59, 30, 6) % and (18, 35, 81, 80) %, respectively. The specimen (S.-J. + Stirrups) showed the best performance in comparison with the other used strengthening techniques used in this study in terms of stiffness and the ultimate load-carrying capacity. The ferrocement jacket (S.-J. + Ferrocement) was found to be the most suitable jacketing system used to enhance the shear capacity in terms of cracking load.