Basrah Journal for Engineering Sciences
Login
Basrah Journal for Engineering Sciences
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Announcements
    • Contact

Search Results for heat-exchanger

Article
Theoretical and Experimental Study of Water Storage Tank with Earth Water Heat Exchanger in Hot Climates Regions

Amer Abduladheem Dakhil, Salman Hashim Hammadi

Pages: 29-35

PDF Full Text
Abstract

Concerning commercial and residential buildings, one of the major parts related to water supply systems is the water storage tanks. For gravity- fed buildings, the tanks must be installed on the roof. In Iraqi summer, the temperature of water in storage tanks reaches above 50 °C due to high solar intensity, which makes it inappropriate for domestic usage. One of the proposed solutions to overcome this problem is feeding the hot water into an earth-water heat exchanger (EWHE) which consists of a set of buried pipes installed underground level to reduce its temperature. The storage tank and the earth-water heat exchanger were studied experimentally and theoretically by using ANSYS 20/FLUENT software to estimating the water temperature in the storage tank and the temperature of the water leaving the EWHE. The most important results obtained theoretically and experimentally that when using pipe length, pipe diameter, and mass flow rate of 100 m, 0.016 m, 0.7 LPM respectively, at a depth of 3 m, the water temperature decreases by about 15 °C. Also, the results have shown a good agreement between the experimental and theoretical works. One can conclude that an earth-water heat exchanger is an effective way to decrease the temperature of the storage water to an acceptable level for domestic usages.

Article
Application of Earth Tube Heat Exchanger and Solar Chimney for Natural Cooling System in Basrah City

Salman H. Hammadi, Alaa Hlaichi Mohammed

Pages: 23-32

PDF Full Text
Abstract

Solar chimney (SC) together with earth to air heat exchanger (EAHE) is being employed as a low-energy consuming technique to remove undesirable interior heat from a building in the hot seasons. A numerical program "FLUENT 6.3 code" of an earth to air heat exchanger (EAHE) is studied for predicting the outlet air temperature and cooling potential of these devices in Basrah climate. Theoretical analyses have been conducted in order to investigate the ventilation in a solar chimney. The investigation into the viability of Low Energy Earth Pipe Cooling Technology in providing thermal comfort in Basrah. The demand for air-conditioning in buildings in Basrah affects the country escalating energy consumption. Therefore, this investigation was intended to seek for an alternative passive cooling to air-conditioning. The passive technology, where the ground was used as a heat sink to produce cooler air, has not been investigated systematically in hot and humid countries. A sub-soil temperature model adapted for the specific conditions in Basrah is presented and its output compared with CFD modeling. The results have shown that the potential of Earth Pipe is providing lower output temperature of air inlet to the room. We found that the resulting temperature at the buried pipe outlet decreases with increasing pipe length, decreasing pipe diameter, decreasing mass flow rate of flowing air in the pipe and increasing depths up to 4m.

Article
Performance Characteristics of Parallel Slip Flow Microchannel Heat Exchanger

Hazim Abdulrazzaq Hanoon, Ahmed K. M. Alshara

Pages: 16-30

PDF Full Text
Abstract

Parallel flow microchannel heat exchanger performance was numerically investigated, for laminar, 3-D, incompressible and steady state flow with slip flow and temperature jump conditions. The continuity, Navier-Stokes equations and the energy equations for the hot and cold fluids were solved by using finite volumes method and SIMPLE algorithm method with FORTRAN code to obtain the velocity and temperature distributions for the two fluids and the separated wall between them. The main investigation parameter that affected on the performance and effectiveness of heat exchanger are: Reynolds number Re, thermal conductivity ratio Kr, Knudsen number Kn, thickness of separating wall, heat capacity ratio Cr and aspect ratio α. Increasing of Reynolds number, Knudsen number, thickness of separating wall, heat capacity ratio and aspect ratio each separately leads to decrease the effectiveness while increasing of thermal conductivity ratio up to 10 leads to increase the effectiveness. Also, it is found that friction number and Nusselt number both decreases with increasing Knudsen number.

Article
Simulation of the Effect of Soil Temperature on Earth - Air Heat Exchanger Behavior

Hussam Hakeem Qasim, Ahmed K. Alshara, Falah A. Abood

Pages: 12-23

PDF Full Text
Abstract

Modern life makes energy, and the source of it is very important. This renewable energy comes from the Earth-Air Heat Exchanger (EAHE) in the soil employed as an air conditioning device for buildings in the climate conditions in Basrah city, south of Iraq. In the present study, the EAHE buried in the soil is simulated numerically using the finite volume method with a soft package. ANSYS: Fluent 2021/R2. A parametric analysis was carried out to determine the effect of three depths ( Z = 1, 2, and 3 m), taking into account the physical properties of the soil in the area under study, which is in the city of Basrah in southern Iraq, at longitude 47.749° and latitude 30.568°, as well as the data and time of 1/6/2023 at 12 p.m., the diameter of the pipe ( D = 7.62, 10.16, and 15.24 cm), and different velocities ( v = 0.5, 1, and 1.5 m/s). The results are presented as a temperature contour and a velocity contour for the performance of EAHE. The important results showed that when the depth of the buried pipe decreases, the temperature of the air outlet and heat exchanger increases; when the diameter decreases, the air outlet temperature from the EAHE and the soil temperature decrease; when the length of the pipe is about 30 m, after this length, the decrease in temperature is very small; and the maximum temperature difference of about 10 °C between the ambient temperature and the outlet temperature of the EAHE was obtained at a depth of 3 m and a velocity of 1 m/s at a diameter of 7.62 cm.

Article
Simulation Absorption Refrigeration System Powered by a Solar Pond

Atyab Safaa Saleem, Salman Hashem Hammadi

Pages: 38-49

PDF Full Text
Abstract

The thermal performance of an absorption refrigeration system powered by solar pond heat was studied, simulated, and evaluated under the climatic conditions of Basra, Iraq. The simulation used MATLAB to solve the heat and mass transfer equations within the three layers of the solar pond (assuming NaCl as the salinity gradient medium) and linked them via a heat exchanger to the absorption refrigeration system to determine the temperatures supplied to the absorption cycle. The absorption cooling system operates on a lithium bromide-water pair and contains an internal heat exchanger between the generator and absorber with an assumed efficiency of 80%. The simulation was conducted over several months of the year, from March to October, and daily climatic variables such as solar radiation and ambient temperature specific to Basra were considered, allowing the system's performance to be evaluated under realistic climatic conditions. The objective was to evaluate the coefficient of performance (COP) of absorption refrigeration systems and demonstrate the feasibility of using solar ponds as a sustainable heat source for cooling in hot regions. The study demonstrated the feasibility of operating an absorption refrigeration system using the thermal energy stored in the lower layer of the solar pond, while maintaining good thermal stability in that layer throughout the day, especially in areas with high solar radiation, such as Basra. The simulation model was developed entirely in MATLAB using fundamental physical equations that describe each component of the solar pond and absorption refrigeration system, without relying on pre-existing components or tables. This provides greater modeling flexibility and a deeper understanding of system behavior under hot climate conditions.

Article
An Experimental Study to Improve Solar Heating Water Using PCM and Integrated with Helical Heat Exchanger

Fahad S. Fahad, Ibrahim Koc

Pages: 72-79

PDF Full Text
Abstract

Solar energy can only be used when it's sunny outside. Therefore, solar heating is only efficient during the day and decreases at night or on overcast days. Consumer energy needs have a distinct seasonal structure, and solar energy cannot completely meet those needs. In order to satisfy customer demand, energy storage is essential. In order to maximize the use of solar energy and to increase the energy and efficiency of the solar absorption system, superior thermal properties of sophisticated materials, such as phase change materials, are important [1]. In the current study, 20 kg of phase change material (PCM) is integrated with solar water heating and fed into a storage tank to enhance the solar water heating efficiency. Helical coil heat exchangers were added to the storage tank as an external load. The trials were conducted in four separate months (September 2021, April, May, and June 2022) that were chosen on the first day. The effectiveness, heat gain, and significance of the phase change material in increasing heating efficiency throughout the day were studied using a range of variables, including water volume flow rate (2, 3, 4, 6, and 8 L/min) and inlet water temperature (25, 30, and 35 °C). The results showed that, given an initial temperature of 25 °C, the daily efficiency range, was 0.58 to 0.65, and that the daily final outlet temperature was enhanced outlet temperature over 65 °C. Additionally, on all test days, the heat released by the phase change material was audible in the evening and increased the utilization time.

Article
Using PCM, an Experimental Study on Solar Stills Coupled with and without a Parabolic Trough Solar Collector

Hazim Jassim Jaber, Qais A. Rishak, Qahtan A. Abed

Pages: 45-52

PDF Full Text
Abstract

Performance a double slope of the solar still Integrated With or without parabolic trough collector is investigated experimentally. To improve the output of a double slope solar still, a number of initiatives have been undertaken, using wax as a phase change material (PCM) with a parabolic trough collector. A parabolic trough collector (PTC) transfers incident solar energy to the solar still through a water tube connected to a heat exchanger embedded in used microcrystalline wax. Experiments were carried out after orienting the basin to the south and holding the water depth in the basin at 20 mm. According to the results obtained, the solar stills with parabolic trough collector have higher temperatures and productivity than solar stills without parabolic trough collector, as well as the ability to store latent heat energy in solar still, allowing fresh water to condense even after sunset. In addition, the parabolic trough collector with phase change material in the double slope solar improves productivity by 37.3 % and 42 %, respectively.

Article
Direct-Contact Evaporation Using Different Refrigerants: A Review

Safaa Hafedh Hayder, Suad Hassan Danook, Hussein Sadiq Sultan

Pages: 34-47

PDF Full Text
Abstract

The direct-contact evaporation method is characterized by its effectiveness in applications of heat exchangers, especially in cooling systems, due to the absence of any heat resistors that prevent the transfer of heat between the cold and hot medium. The direct contact heat transfer depends mainly on how quickly the heat is taken by the bubbles of the evaporative refrigerant from the liquid and the increase in its volume up to the top of the heat exchanger, which is usually a cylindrical liquid column so that the temperature drop therein is uniform and even. There is much research on the method of heat transfer by direct contact. In this research, we collected and summarized most of the theoretical and practical researches that examined this method with the most important findings.

1 - 8 of 8 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Basrah Journal for Engineering Sciences

College of Engineering, University of Basrah

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, University of Basrah, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.