Go to Editorial ManagerHuman beings are facing an unprecedented rise in temperature rates not recorded for years. HVAC (heating, ventilation, and air conditioning) systems have been created and enhanced to solve this issue. Cooling load must be estimated with accepted methodologies before designing an efficient and effective air conditioning system. Companies, researchers, institutions, and others advise and develop many cooling load calculation methods. Each one of these methods has its advantages and disadvantages and may give a slightly different result for the same case. For each building, whether it was residential or commercial buildings, gyms, or shopping malls, before making the decision on (HVAC) systems to be used, both heating and cooling loads should be obtained as correctly as possible to minimize expenses as possible. Since the HVAC system consumes the most energy in an air-conditioned building, an accurate method of cooling load estimation is necessary. Consequently, an energy-efficient air conditioning system reduces greenhouse gas emissions into the atmosphere while also saving money on electricity. Two cases have been compared and studied, one in Dubai UAE, and the other in Baghdad Iraq. Three different methods, HAP, hand calculation method (CLTD/SCL/CLF), and MS-EXCEL E20 form sheet were used to compare the accuracy of the results for cooling load. Results of E20 and HAP are very close to each other with high accuracy for peak load, the big difference can be found between the CLTD method and the other two methods. The value of the maximum difference percentage was found between CLTD and E20 equals 3.28% and 7.96%, on the other hand, the lowest difference was equals to 0.3% and 1.51% between HAP and E20 results for Baghdad and Dubai respectively. Traditional and local materials came from local factories, used in buildings played a big effect on the results, which may not match those materials stated in the ASHRAE or CARRIER tables, which need to be considered in the results and calculation procedure. However, all methods have a percentage of difference but all results are within the accepted range and are applicable for practical cases. Of course, this percentage is minimal with some methods and maximum with others.
In several countries, residential buildings are responsible for high energy consumption. The majority of energy is consumed on air conditioning to ensure maximum indoor comfort. In Iraq, the demand for electricity increases significantly, especially during the summer for cooling purposes. In this paper, two technologies are proposed for buildings to reduce the cooling load. These approaches included the use of phase- changing materials (PCM) in different locations in the walls and roof, in addition to roof shading by galvanized iron. The effects of these proposals were simulated in the latest software tool (designbuilder) and compared with the standard building model. The results were clear when PCM was installed on the outer surface of the wall and roof, which achieved the highest reduction in the cooling load of about 18 %. While the roof shading method using corrugated galvanized iron proved its effectiveness by decreasing the cooling load to 5 % compared to the standard case.
The present work is aimed to reduce the annual electric energy consumption in a residential building in Basrah city through introducing a standardized rule for the annual electrical consumption for the cooling and heating purposes. This work will concentrate on all parameters which help to go toward the optimum use of thermally efficient house. The building energy analysis program e-Quest was used to simulate the annual energy consumption for a typical residential house built with different types of building materials. Transfer function cooling load calculation was used. The results showed that for the Base- House, the thermal transmission through the walls and roof constitutes more than half of the total peak cooling load. It was found that a house built with thermo-stone causes 5.9% reduction of the annual cooling energy consumption, and 12.4% in the annual heating energy consumption. However, insulating the Base- House causes a significant reduction in the air conditioning equipment capacity and consequently reduction in cooling energy consumption by 23%, and reduces the heating energy consumption by 42.8%. Finally this work presents a useful planning to developed building design which reduces the electrical energy consumption.
In this work, both energy and exergy analyses have been carried out on General Electric (GE) gas turbine unit found in Khor Al-Zubair gas turbine power plant located in Basra, Iraq. The analysis covers the ISO (international standards organization) operating conditions in addition to actual operating data recorded for one month in hot season July 2016. The feasibility of adopting a vapor compression cycle (VCC) for cooling the intake air is evaluated. Generally, the study reveals an obvious drop off for most plant performance characteristics while operating during the hot season. Energy and exergy analyses show that adopting the vapor compression cycle to enhance Khor Al-Zubair GE unit could improve the power output by 20% and 27% in case of part-load and full-load conditions respectively. Both of first and second law efficiencies could be improved by 3.5% at part- load and 9% at full load. The expected cooling load needed for the unit is in the range of 2697 to 3024.5 TR according to part- load and full-load operation respectively. Only total irreversibility of the unit is expected to increase in case of adopting VCC and this will not impair the improvement in second law efficiency of the unit. Among the unit components, combustion chamber has the largest computed irreversibility. Further improvement is recommended by utilizing the released heat energy to the atmosphere, which is characterized by significant work potential.
In this paper, energy and exergy concepts have been carried out on one of the largest gas turbine power plants in Iraq (Rumaila-Basra). Both ISO operating conditions as well as actual operating data recorded for one month in hot season are considered. Results indicate that a lot of heat energy accompanied with remarkable exergy is discharged to the atmosphere. Also, it is found that the combustion chamber has the largest exergy destruction among the plant components. Possibility of cooling the intake air drawn by the compressor and its effects on the plant performance is studied. The required cooling load is found to be in the range 3379 T.R for part load operation to 4723.3 T.R for full load operation.