Go to Editorial ManagerIn this work, both energy and exergy analyses have been carried out on General Electric (GE) gas turbine unit found in Khor Al-Zubair gas turbine power plant located in Basra, Iraq. The analysis covers the ISO (international standards organization) operating conditions in addition to actual operating data recorded for one month in hot season July 2016. The feasibility of adopting a vapor compression cycle (VCC) for cooling the intake air is evaluated. Generally, the study reveals an obvious drop off for most plant performance characteristics while operating during the hot season. Energy and exergy analyses show that adopting the vapor compression cycle to enhance Khor Al-Zubair GE unit could improve the power output by 20% and 27% in case of part-load and full-load conditions respectively. Both of first and second law efficiencies could be improved by 3.5% at part- load and 9% at full load. The expected cooling load needed for the unit is in the range of 2697 to 3024.5 TR according to part- load and full-load operation respectively. Only total irreversibility of the unit is expected to increase in case of adopting VCC and this will not impair the improvement in second law efficiency of the unit. Among the unit components, combustion chamber has the largest computed irreversibility. Further improvement is recommended by utilizing the released heat energy to the atmosphere, which is characterized by significant work potential.
In this paper, energy and exergy concepts have been carried out on one of the largest gas turbine power plants in Iraq (Rumaila-Basra). Both ISO operating conditions as well as actual operating data recorded for one month in hot season are considered. Results indicate that a lot of heat energy accompanied with remarkable exergy is discharged to the atmosphere. Also, it is found that the combustion chamber has the largest exergy destruction among the plant components. Possibility of cooling the intake air drawn by the compressor and its effects on the plant performance is studied. The required cooling load is found to be in the range 3379 T.R for part load operation to 4723.3 T.R for full load operation.
In this study, a numerical investigation has been carried out for single phase flow behavior for thirty six internally finned tubes to demonstrate the effect of axial pitch to fin height ratio (p/e) for 0.8≤p/e≤6.345, helix angle of internal fins (β) for 30°≤β≤70°, apex angle of internal fins (α) for 0°≤α≤53.13°, internal fin height (e) for 0.6mm≤e≤1.0mm, internal tube diameter (di) with 14 mm and Reynolds number (Re) of single phase flow for 10000≤Re≤50000 on enhancement of forced convection heat transfer and reduction of friction factor by using ANSYS CFX program. It solves the three- dimensional Navier-Stokes equations for steady state turbulent with SST model and enhance wall treatment. The numerical analysis provided at fully developed velocity and temperature. Numerical results showed that the smallest axial pitch to fin height ratio (p/e) =0.8 and with apex angle α=10 degree provided enhancement of heat transfer of 2.8 to 3.55 times higher than of smooth tube. Finally, present numerical results are seen to be in good agreement with literature experimental correlations.
In this research, a two – dimensional numerical investigation is conducted to show the ability of the jet-ejector to prepare the air – methane mixture at different equivalence ratio. The basic dimensions (diameters ratio, throat length, angle α , and angle θ ) of the jet-ejector are taken into account on calculating the equivalence ratio. The results showed that the ratio of the diameters has a higher effect than other parameters on preparing a mixture for equivalent ratios including both rich and lean mixture. The rest of the factors did not have a significant effect on the value of the equivalence ratio, and only had a role in preparing an equivalence ratio for rich mixture type.