×
The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerA numerical simulation of the effect evaluation of heat loss and temperature distribution along the wellbore is performed, for two models, the first is an open hole (without perforation) and the other is a perforated vertical wellbore. In this study, the Computational Fluid Dynamics (CFD) software code ANSYS FLUENT 15.0 has been used, for simulate a model of 3-D turbulent flow with stander k-ϵ model. The results of this show that, increasing the heat losses leads to an increase in the temperature gradient, while the temperature gradient decreases with increasing inlet main velocity. Also, the temperature of the produced crude oil decreases with increasing the length of the wellbore.
An experimental study has been implemented to study the effect of the central radial groove on the bearing pressure distribution. This study is based on the artificial neural network in the prediction of the complex and uncertain positions. Both width and depth of the groove have been varied at some magnitudes in order to investigate their effects on the pressure distribution and the stability of the bearing. Also, the effect of the groove parameters on the noise at the bearing situation in the systems have been analyzed and discussed. The results show that the use of neural network in the prediction of some points with range is very powerful in the minimization of the overall cost of groove design.
Flaring systems used in oil production systems have a significant impact on both the economy and the environment as they discharge large quantities of burned gases of elevated temperature to the atmosphere that have the potential to be used in some applications. This study aims to investigate the economic losses incurred due to the combustion of gases not utilized in the Rumaila oil field in Basrah, the southern region of Iraq. Additionally, the potential to use flare gases for power generation and water desalination was studied. The mathematical models established by the U.S. Environmental Protection Agency (EPA) were utilized in this study to estimate and calculate the expected losses and used MatLab Ver. R22 to get result. The result leads to expected annular economic losses to reach $ 347,735,700. Also, the flare gases can be used to produce electric power of 1175 MW per year, it can be used for producing desalinating water of 115,911,900 m 3 for thermal desalination and 173,867,850 m 3 for membrane desalination.
The direct-contact evaporation method is characterized by its effectiveness in applications of heat exchangers, especially in cooling systems, due to the absence of any heat resistors that prevent the transfer of heat between the cold and hot medium. The direct contact heat transfer depends mainly on how quickly the heat is taken by the bubbles of the evaporative refrigerant from the liquid and the increase in its volume up to the top of the heat exchanger, which is usually a cylindrical liquid column so that the temperature drop therein is uniform and even. There is much research on the method of heat transfer by direct contact. In this research, we collected and summarized most of the theoretical and practical researches that examined this method with the most important findings.