The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerThis paper presents a pressure drop analysis in perforated vertical wellbores for different perforation parameters. The effect of the density of the perforations (number of perforation), the phase angle of the perforations, the diameter of the perforation and the flow rate of the crude oil from the perforations on the pressure drop and the productivity index of the perforated vertical wellbores were studied. The analysis of the vertical wellbore was performed numerically using ANSYS FLUENT 15.0 software. Three dimensional, steady-states, turbulent and incompressible fluid flow is assumed during the numerical solution of the governing equations. The results of this study show that, increased perforation density of the perforated vertical wellbore caused an increase in pressure drop, and also, decreased productivity index due to increasing the friction losses. Friction pressure drop has a significant effect on crude oil flow into the wellbore. When the main velocity is 1.5 m/s and the inlet velocity from the perforations is 2 m/s, the friction pressure drop is about 66 % and the acceleration pressure is approximately 34 % of the total pressure drop.
Thermal steam power plants represent the most important and dependable type for supplying the base load of electricity around the world. The thermos-economic analysis is an important tool for improving the performance of thermal steam power plants. In the present study, a thermo-economic analysis of a simple steam power plant for different boiler pressure was performed. The analysis comprises the energy, exergy, entropy, economics, and exergy-economic of a simple cycle steam power plant for different boiler pressure. The analysis was performed for a simple steam power plant with the constant output power of 10 MW and the boiler pressure is varied from 10 bar to 100 bar by a step of 10 bar. For each boiler pressure and constant output power, firstly, the fuel mass flow rate, steam flow rate, energy and exergy efficiency, and cost of electricity were calculated. Secondly, entropy generation, exergy destruction, and exergy efficiency for each component were calculated. Finally, exergy destruction economics for each component of the plant was performed. The results reveal that increasing the boiler pressure from (10 to 100 bar) for constant output power reduces the cost of electricity from (0.135 to 0.1025 $/kWh) due to a decrease in the fuel mass flow rate and an improvement in the thermal cycle and exergy efficiency. Also, when the boiler pressure increases, the exergy destruction for the pump increases, the exergy destruction for the boiler decreases, the exergy destruction for the turbine increases, and the exergy destruction for the condenser decrease.
The direct-contact evaporation method is characterized by its effectiveness in applications of heat exchangers, especially in cooling systems, due to the absence of any heat resistors that prevent the transfer of heat between the cold and hot medium. The direct contact heat transfer depends mainly on how quickly the heat is taken by the bubbles of the evaporative refrigerant from the liquid and the increase in its volume up to the top of the heat exchanger, which is usually a cylindrical liquid column so that the temperature drop therein is uniform and even. There is much research on the method of heat transfer by direct contact. In this research, we collected and summarized most of the theoretical and practical researches that examined this method with the most important findings.
Human beings are facing an unprecedented rise in temperature rates not recorded for years. HVAC (heating, ventilation, and air conditioning) systems have been created and enhanced to solve this issue. Cooling load must be estimated with accepted methodologies before designing an efficient and effective air conditioning system. Companies, researchers, institutions, and others advise and develop many cooling load calculation methods. Each one of these methods has its advantages and disadvantages and may give a slightly different result for the same case. For each building, whether it was residential or commercial buildings, gyms, or shopping malls, before making the decision on (HVAC) systems to be used, both heating and cooling loads should be obtained as correctly as possible to minimize expenses as possible. Since the HVAC system consumes the most energy in an air-conditioned building, an accurate method of cooling load estimation is necessary. Consequently, an energy-efficient air conditioning system reduces greenhouse gas emissions into the atmosphere while also saving money on electricity. Two cases have been compared and studied, one in Dubai UAE, and the other in Baghdad Iraq. Three different methods, HAP, hand calculation method (CLTD/SCL/CLF), and MS-EXCEL E20 form sheet were used to compare the accuracy of the results for cooling load. Results of E20 and HAP are very close to each other with high accuracy for peak load, the big difference can be found between the CLTD method and the other two methods. The value of the maximum difference percentage was found between CLTD and E20 equals 3.28% and 7.96%, on the other hand, the lowest difference was equals to 0.3% and 1.51% between HAP and E20 results for Baghdad and Dubai respectively. Traditional and local materials came from local factories, used in buildings played a big effect on the results, which may not match those materials stated in the ASHRAE or CARRIER tables, which need to be considered in the results and calculation procedure. However, all methods have a percentage of difference but all results are within the accepted range and are applicable for practical cases. Of course, this percentage is minimal with some methods and maximum with others.
A numerical simulation of the effect evaluation of heat loss and temperature distribution along the wellbore is performed, for two models, the first is an open hole (without perforation) and the other is a perforated vertical wellbore. In this study, the Computational Fluid Dynamics (CFD) software code ANSYS FLUENT 15.0 has been used, for simulate a model of 3-D turbulent flow with stander k-ϵ model. The results of this show that, increasing the heat losses leads to an increase in the temperature gradient, while the temperature gradient decreases with increasing inlet main velocity. Also, the temperature of the produced crude oil decreases with increasing the length of the wellbore.
The thermoelectric behavior of different materials under various conditions has been investigated numerically by using the heat transfer module of the COMSOL Multiphysics software platform. A simulation study of the thermoelectric materials (TEM) performance was created by altering the current applied from 0.1 to 1.0 A and setting the hot side temperature (T H ) as 273 K. The impact of different performance metrics, such as cold side temperature and output voltage, has been proven and investigated. It has been shown that the material of the thermoelectric legs', length of leg, and thickness of electrodes significantly impact the thermal and electrical performance of the thermoelectric (TE) module. Appropriate ranges have been studied in the simulation, such as the amperage values applied to the unit as mentioned above, the length of the leg within a range of 1 to 8 mm, and the thickness of the electrode with different values of 0.1 to 0.5 mm, which will achieve excellent performance for the Thermoelectric unit. Modeling and simulation results demonstrated and revealed the optimal and potential use of bismuth telluride (Bi 2 Te 3 ) as well as lead telluride (PbTe) as suitable for Peltier cooling applications. As for the use of cobalt triantimonide (CoSb 3 ), it is in contrast to the two previous metals, as it is effective and appropriate if applied to power generation. The results are validated with another study from the literature, and there is an excellent agreement with an error rate that does not exceed 0.164%.
An experimental study has been implemented to study the effect of the central radial groove on the bearing pressure distribution. This study is based on the artificial neural network in the prediction of the complex and uncertain positions. Both width and depth of the groove have been varied at some magnitudes in order to investigate their effects on the pressure distribution and the stability of the bearing. Also, the effect of the groove parameters on the noise at the bearing situation in the systems have been analyzed and discussed. The results show that the use of neural network in the prediction of some points with range is very powerful in the minimization of the overall cost of groove design.
The Atmospheric Water Generator (AWG) is an environmental water recovery that easily dehumidifies water vapor moisture from the air. This article presents an experiment to construct an AWG model using solar energy as a source of power. An experimental and numerical study for a device of (AWG) is performed. The experimental work is performed at Basrah city, located in the south of Iraq, during August and September of 2019 and March of 2020. The theoretical results are calculated by EES and the numerical study has been conducted by the (ANSYS19/CFD/ FLUENT) program. The experimental device is tested for different days with different climate conditions. The Maximum water production obtained is 3.4 L/day from all the testing days, for different hours of operation when the relative humidity in the range of (45 – 95 %) and the temperature range from 17 °C to 45 °C. The results shown that, the water production rate is increased with increasing humidity, temperatures, hours of operation, and model size.
Flaring systems used in oil production systems have a significant impact on both the economy and the environment as they discharge large quantities of burned gases of elevated temperature to the atmosphere that have the potential to be used in some applications. This study aims to investigate the economic losses incurred due to the combustion of gases not utilized in the Rumaila oil field in Basrah, the southern region of Iraq. Additionally, the potential to use flare gases for power generation and water desalination was studied. The mathematical models established by the U.S. Environmental Protection Agency (EPA) were utilized in this study to estimate and calculate the expected losses and used MatLab Ver. R22 to get result. The result leads to expected annular economic losses to reach $ 347,735,700. Also, the flare gases can be used to produce electric power of 1175 MW per year, it can be used for producing desalinating water of 115,911,900 m 3 for thermal desalination and 173,867,850 m 3 for membrane desalination.