The Influence of Aggregates on Punching Shear Resistance of Slabs-Without Shear Reinforcement

Abstract

The choice of aggregate type in producing reinforced concrete depends on the availability of the source sometimes and the intended concrete requirements like lightweight or normal aggregate concrete or high strength concrete. The punching shear resistance is being considered to be influenced by numbers of parameters including aggregate size and types. These parameters have not accounted in most of codes of design and have given a little attention by researchers. Most of available knowledge are based on outcomes from experimental works on beams. In this paper, the considerable slab tests without shear reinforcement are collected from literature in which aggregate types and sizes are given and they were failed in punching. The test results are compared to those calculated by ACI, EC2 and CSCT. The deficits of shear resistance are found clear where high compressive strength is combined with reinforcement ratio.

References

  1. Eurocode 2, Design of concrete structures, Part 1-1, General rules and rules for buildings, EN 1992-1-1, CEN, Brussels, Dec 2004.
  2. ACI 318-11, Building code requirements for structural concrete, American Concrete Institute, Farmington Hills, MI, USA, 2011
  3. A. Muttoni, Punching shear strength of reinforced concrete slabs without transverse reinforcement, ACI Structural Journal, V105 No 4, July-August 2008, pp. 440-450.
  4. Fib Model code 2010, First complete draft, Vol. 2, Bulletin 56, fib, Lausanne.
  5. J. Walraven , J. Stroband, Shear capacity of High- strength concrete beams with shear reinforcement. Symposium on High-Strength Concrete, 1999, Sandefjord, Norway.
  6. H. P. J. Taylor, Investigation of the forces carried across cracks in reinforced concrete beams in shear by interlock of aggregate. No. TR 42.447 Tech. Rpt.1970.
  7. A.N.N. Kawar, Punching Strength of Plain Concrete, Disseration, Dept.of Civil Engineering, University of Birmingham,1980.
  8. Regan P.E., Kennedy Reid I.L., Pullen A.D. and Smith D.A., The influence of aggregate type on the shear resistance of reinforced concrete, The Structural Engineer, V83 No 23/24, 6 Dec 2005, pp 27-32.
  9. Sagaseta J., The influence of aggregate fracture on the shear strength of reinforced concrete beams: an experimental and analytical research project. Structural Concrete, 14 (2013), NO.4. pp.401-414.
  10. Y. Hamadi, P. Regan, Behaviour of normal and light weight aggregate beams with shear cracks. The structural Engineer.58B (4), 1980, pp.71-79.
  11. Sherwood, G. Edward, C. Evan , and P. C. Michael, "Effect of aggregate size on beam-shear strength of thick slabs." ACI Structural Journal 104.2(2007): 180.
  12. J. Walraven, and N. Al-Zubi, Shear capacity of light weight concrete beams with shear reinforcement. Proceedings ofSymposium on Lightweight Aggregate Concrete, 1995, Sandefjord, Norway.
  13. E. Rizk and H. Marzuk, Experimental validation of minimum flexural reinforcement for thick high- strength concrete plates, ACI Structural Journal, Vol. 108 No 3, May-June 2011, pp 332-340.
  14. Rizk E., Marzuk H. and Hussein A., Punching shear of thick flat plates with and without shear reinforcement, ACI Structural Journal, Vol. 108, No.5, Sept-Oct 2011, pp 581-591.
  15. Moe J., Shearing strength of reinforced concrete slabs and footings under concentrated loads, Development Dept. Bulletin D47. Portland Cement Association, Skokie, Illinois, 1961.
  16. Regan P.E., Symmetric punching of reinforced concrete slabs, Magazine of Concrete Research, Vol.38, No 136, Sept 1986, pp 115-128.
  17. Ramdane, K., Punching shear of high performance concrete slabs, Proceedings of the Fourth International Symposium, V.3, Paris, France, 1996, pp. 1015-1026.
  18. Kinnunen S.,Nylander H. And Tolf P.,Plattjocklekens inverkan pa betongplattors hallfasthet vid genomstansning. Forsok med rektangulara, (Influence of slab thickness on the punching strength of rectangular slabs), Meddlande nr 137, Institutionen for Byggnadsstatik,KTH, Stockholm, 1990.
  19. Tolf P., Plattjocklekens inverkan pa betongplattors hallfasthet vid genomstansning-Forsok med cirkulara plattor, (Influence of slab thickness on the punching strength of concrete slabs- Tests of circular slabs) Meddelande nr. 146, Institutionen for Byggnadsstatik, KTH Stockholm, 1988.
  20. Hallgren M., Punching shear capacity of reinforced high strength concrete slabs, TRITA-BKN Bulletin 23, Dept. Of Structural Engineering, KTH Stockholm, 1996.
  21. Marzouk H. And Hussein A., Experimental investigation on the behaviour of high-strength concrete slabs, ACI Structural Journal, V88 No6, Nov-Dec 1991,pp 701-713.
  22. Regan P.E., Symmetric punching of reinforced concrete slabs, Magazine of Concrete Research, Vol. 38, No 136, Sept 1986, pp 115-128.